Blender Git Loki
Git Commits -> Revision 89b5c9d
October 28, 2020, 08:05 (GMT) |
Fix T81633 Workbench: TAA never resolve when enabling both X-Ray and cavity This was caused by a wrong flag equality check when in xray mode because the xray mode was masking the effect option flags that are not supported in this mode. This means the never passed and the TAA was reset before every redraw, leading to infinite rendering. |
Commit Details:
Full Hash: 89b5c9d433793ba7f34ee9b9f3008cd0a4608374
Parent Commit: f994c8c
Committed By: Jeroen Bakker
Lines Changed: +17, -3
1 Modified Path:
/source/blender/draw/engines/workbench/workbench_data.c (+17, -3) (Diff)